[Consultation]- Samion[62.219.92.221]在2018-05-27 16:27 说:JT6318A |
Hi
I'm can test rechargeable battery over JT6318A?
You can send me all function of JT6318A
BR
Samion |
Administrators Replying: we can contact by e-mail(Alan@jartul.com).
I seldom log in website.
our e-load can test battery |
[Others]- Anonymous[61.1.169.50]在2022-10-01 13:52 说:Inquiry |
Hello Jartul Team, Myself Balraj from India. We are the leading manufacturers of 2WEV in india. We have an requirement of DC Power Supply and DC Electronic Load for Testing of Charger and DC-DC Converter. I have already shared the requirements to you via mail from balraj.k@purenergy.co.in mail id. Looking forward to have a good business with you.
|
[Suggestion]- Anonymous[122.176.204.174]在2022-05-23 14:44 说:PD3.0 |
i need PD and QC Charger Checking DC load MAchine
|
[Suggestion]- Yogesh Sain[47.31.167.133]在2022-02-28 20:12 说:QUOTATION |
jt6311A , DC electronic load with stendred accessories
voltage range - 0-15v ,current range - 0-30Amp , wattage - 150w |
[Suggestion]- Yogesh Sain[47.31.167.133]在2022-02-28 20:12 说:QUOTATION |
jt6311A , DC electronic load with stendred accessories
voltage range - 0-15v ,current range - 0-30Amp , wattage - 150w |
[Consultation]- manoj kumar[122.177.101.104]在2021-10-25 14:00 说:hi |
hi |
[Others]- A V Reddy[183.82.1.91]在2021-10-20 19:23 说:MANAGING DIRECTOR |
Hi, good evening.. I am Venkat Reddy Adla from Accord Power Conversion Pvt. Ltd India. Few years back we purchased 4 Nos of JT series test loads, all the units are working till date fine..
Now, we started producing Electric Vehicle Chargers, for this please suggest your test systems.
The required voltage range could be 3V - < 90 VDC and the current can up to maximum of 50.0 Amps, the power of the test system could be 1000 W, 2000 W, and up to 5000 W.
we required each model 4-5 Nos, please advise us to proceed further.
me email id: venkatreddy@accordpower.in, whatsapp : +91 9963 800599
Thanks,
Expecting early reply. |
[Consultation]- Anonymous[103.117.12.168]在2021-09-03 14:12 说:Instrument installation |
I have purchase JT6310A . need to test mobile charger on CC,CV, Short circuit,Open circuit simultaneously in production line . Please suggest for how to configure test file |
[Consultation]- Ramises Galila[116.50.216.44]在2021-08-09 12:04 说:Calibration inquiry |
Seeking assistance if you are providing calibration services for Electronic load test equipment of your brand.
|
[Consultation]- Yash[45.118.167.90]在2021-04-20 21:28 说:Inquiry |
I have jt6111 dc electronics load |
|